UV-A UV Radiometer |
INTRODUCTION£º |
The new UV-A UV-Radiometer is a high-precision and high-efficiency UV energy radiation detection instrument, mainly suitable for the electronic component industry, spray coating industry, UV coating industry, printing industry, and other industries that need to be used to test the intensity and energy of various UV light sources such as high-pressure mercury lamps, low-pressure mercury lamps, and plate lamps. Not only can UV energy and light intensity be tested, but temperature can also be tested to perfectly meet all data requirements of the manufacturing process. |
Product features: |
|
¡ï Intelligent UV-Radiometer, automatically identifying test wavelengths |
|
Main parameters: | |
Spectral range: UVA (320-395nm) Range: 0.1-20000mw/cm2 0.1-999999mj/cm2 Temperature limit: -55~125 ¡æ Screen type: Color LCD screen Resolution: 0.1mw/cm2 0.1mj/cm2 (high-power version) Error range: ¡À 5% Storage interval: Power storage interval 0.1S/time Temperature storage interval 0.1S/time Temperature error: ¡À 1 ¡æ Data storage: 5 sets of data, with a total duration of 15 minutes Measurement mode: automatic measurement mode, manual measurement mode Data transmission: Yes Analysis software: Yes Print report: Yes Sampling speed: 0.01 seconds/time Unit switching: MW/cm2 W/cm2 Power type: Two No. 7 alkaline batteries Instrument size: circular diameter 120mm * height 13mm Instrument weight: net weight 180g Packaging weight: 1200g Outer box size: 240mm * 205mm * 80mm |
|
Precautions: | |
1. Use two No. 7 alkaline batteries. After opening the battery cover, install the battery according to the positive and negative pole markings (see inside the battery box). When the battery level on the instrument display screen is low, it should be replaced in a timely manner. 2. Optical precision instruments should avoid severe collisions and be used in a dry and clean environment as much as possible; Please store the detection window facing downwards to avoid contamination on the glass sheet of the measurement sensing window; Be sure to turn off the power after measuring. 3. Please remove the battery if not in use for a long time to avoid damaging the machine with battery filtrate. 4. Do not wipe the sensing window glass with your hands, keep the sensing window clean. 5. To ensure the consistency of instrument data, instrument data calibration can only be conducted through the manufacturer's calibration software. 6. By installing software programs on a USB drive, data analysis, importing and exporting data, and printing test reports can be performed. |
|